APPLICATION RATES

Typical Dilution Factors and Solution Application Rates for a 5/8" to 1" Crust

 

 

Soil

Application

 

Dilution

(product to water)

Trans/Seal I

required

(gal/acre)

Application Rate

(gal/yd2)

Water required

(gal/acre)

Penetrometer Test

(tons/ft2)

Drop Ball Test Thickness of Crust

(in)

Heavy 1 to 40 65 .54 2,600 1.5 Pass 5/8-1
Heavy 1 to 60 43 .54 2,600 1.0 Pass 5/8-1
Moderate 1 to 80 32 .54 2,600 .75 Pass 5/8-1
Light 1 to 100 26 .54 2,600 .75 Pass 5/8-1
Light 1 to 150 17 .54 2,600 .50 Pass 5/8-1

 

 

Typical Dilution Factors and Solution Application Rates for a 1/4" to 3/8" Crust

 

 

Soil

Application

 

 

Dilution

(product to water)

Trans/Seal I

required

(gal/acre)

Application Rate

(gal/yd2)

Water required

(gal/acre)

Penetrometer Test

(tons/ft2)

Drop Ball Test Thickness of Crust

(in)

Light 1 to 60 24 .3 1,500 .75 Pass 1/4-3/8
Light 1 to 80 18 .3 1,500 .50 Pass 1/4-3/8

 

 

Traffic Area Application

 

 

Product

 

Use/Treatment

Dilution Ratio Range Application Rate

(gal/yd2)

Note
Trans/Seal I Road/Parking Lot 1 to 40 1.35 1,2,3

 

Non-Traffic Area Application

 

 

Product

 

Use/Treatment

Dilution Ratio Range Application Rate

(gal/yd2)

Note
Trans/Seal I Vacant Lot 1:60 to 1:150 .54 1,2,3

 

 

Notes

 

1.    Topical application rates shown are to obtain 1/2 to 1 inch of penetration.  Higher applications rates should be used if greater penetration is needed.  Windrow rate shown is to give sufficient penetration to form a 4-6 inch thick  temporary travel surface.

 

2.    The dilution ratio (concentrate: water) is variable, and shall be appropriate for the intended use, and local soil and weather conditions, as proposed by the Contractor and  agreed upon by the Control Officer.

 

3.    Application rate of mixed solution at the typical dilution ratio. First application follows removal of the windrow. Second application follows replacement of the windrow. Third application, if needed follows the second application.

 

Windrow:  Method of making a temporary road surface.  A 4 to 6 inch layer of soil is scraped off the surface.  The surface is treated with dust suppressant. The windrow scraped off the surface.  The surface is treated with dust suppressant.  The windrow is scraped back onto the surface and another treatment of dust suppressant is applied.  A compaction step may be necessary.

 

Copyright © 2005 [Fluid Tech, Inc.]